BUILD10
Local Service PartnersAI PartnersProduct
About UsContact
BUILD10
← KNX via Matter catalogProject shortlist (0)
B.E.G. PD4N-KNXs-BA-FC 93535

B.E.G.

B.E.G. PD4N-KNXs-BA-FC

KNX presence/motion sensor with ambient-light measurement.

Product type
Sensors & inputs
Model / SKU
93535
KNX connection
KNX; consult the exact model documentation and ETS application

Connecting this device to Matter

This product uses KNX. A compatible bridge can expose selected functions to Matter through its IP connection. The KNX device itself does not become a Matter over Thread device.

Functions to map through a bridge

  • Occupancy
  • Illuminance

Selected native KNX functions can be mapped using a suitable Matter bridge. Additional probes, contacts, couplers, controlled equipment or temperature controllers may be required as described below. Exact device–bridge combinations have not been tested.

Commission the KNX installation in ETS, then configure the bridge with the required group addresses, data types and status feedback. Check the exact bridge firmware and your Matter platform. Native KNX functions, electrical ratings and Matter functions are separate specifications.

Function mapping is not a tested device–bridge pair or individual Matter certification for this KNX model. Protection functions and essential local automation should remain in the KNX installation.

Bridge options by function

These options match the product’s KNX functions to capabilities documented for a bridge. Open the bridge for its requirements and limitations.

1Home Voice & Visu

Function mapping, not a tested device–bridge pair

Occupancy · Illuminance

Proposed from documented KNX and bridge function types. Verify the exact ETS application, required command/status objects, KNX Secure access and receiving-app support. This model–bridge pair has not been physically tested.

View mapping source ↗

1Home Server KNX Pro

Function mapping, not a tested device–bridge pair

Occupancy · Illuminance

Proposed from documented KNX and bridge function types. Verify the exact ETS application, required command/status objects, KNX Secure access and receiving-app support. This model–bridge pair has not been physically tested.

View mapping source ↗

Atios KNX Bridge

Function mapping, not a tested device–bridge pair

Occupancy · Illuminance

Proposed from documented KNX and bridge function types. Verify the exact ETS application, required command/status objects, KNX Secure access and receiving-app support. This model–bridge pair has not been physically tested.

View mapping source ↗

Technical specifications

Presence · Illuminance

Product number
93535
Detection technology
Passive infrared
Voltage
via KNX BUS
Dimensions
Ø 106 x 74 mm
Bus current consumption
12 mA
Detection area
horizontal 360° (Ceiling mounting)
Range
max. Ø 24 m across max. Ø 8 m towards max. Ø 6.4 m seated
Monitored area (tangential movement)
450 m² / 2.5 m mounting height
Mounting height min./max./recommended
2 m / 10 m / 2.5 m
Degree / class of protection
IP20 / Class III
Ambient temperature
-25 °C to +55 °C
Housing
polycarbonate, UV-resistant
Specifications with sources (10)

Voltage

via KNX BUS

View specification source ↗

Dimensions

Ø 106 x 74 mm

View specification source ↗

Bus current consumption

12 mA

View specification source ↗

Detection area

horizontal 360° (Ceiling mounting)

View specification source ↗

Range

max. Ø 24 m across max. Ø 8 m towards max. Ø 6.4 m seated

View specification source ↗

Monitored area (tangential movement)

450 m² / 2.5 m mounting height

View specification source ↗

Mounting height min./max./recommended

2 m / 10 m / 2.5 m

View specification source ↗

Degree / class of protection

IP20 / Class III

View specification source ↗

Ambient temperature

-25 °C to +55 °C

View specification source ↗

Housing

polycarbonate, UV-resistant

View specification source ↗

Sources & limitations

Product research reviewed: Nov 5, 2026. This is separate from price, stock and installation-test dates.

Model, firmware & function limitations (3)
  • Native lighting/HVAC automation and proprietary detector settings are not automatically exported to Matter.
  • Requires an independently selected KNX-to-Matter bridge and ETS group-address mapping. Exact device/bridge pairing has not been physically tested.
  • Official manufacturer product page confirms the KNX product and the listed native functions. Matter export is a function-level integration candidate, not a manufacturer-tested exact pairing.
Manufacturer documentation & sources (1)
  • B.E.G. — PD4N-KNXs-BA-FC ↗Reviewed Nov 5, 2026
← Back to resultsOpen project shortlist

© 2026 BUILD10

HomeRecommended DevicesContactPrivacy Policy