Elsner Elektronik Suntracer KNX basic 20...30 V DC | KNX via Matter | BUILD10
BUILD10
Local Service PartnersAI PartnersProduct
About UsContact
BUILD10
← KNX via Matter catalogProject shortlist (0)
Elsner Elektronik Suntracer KNX basic 20...30 V DC Suntracer KNX basic 20...30 V DC

Representative image of the product family. Confirm the exact model and configuration.

Elsner Elektronik

Elsner Elektronik Suntracer KNX basic 20...30 V DC

KNX weather station with outdoor measurements for building automation.

Product type
Sensors & inputs
Model / SKU
Suntracer KNX basic 20...30 V DC
KNX connection
KNX; consult the exact model documentation and ETS application

Connecting this device to Matter

This product uses KNX. A compatible bridge can expose selected functions to Matter through its IP connection. The KNX device itself does not become a Matter over Thread device.

Functions to map through a bridge

  • Temperature
  • Illuminance

Selected native KNX functions can be mapped using a suitable Matter bridge. Additional probes, contacts, couplers, controlled equipment or temperature controllers may be required as described below. Exact device–bridge combinations have not been tested.

Commission the KNX installation in ETS, then configure the bridge with the required group addresses, data types and status feedback. Check the exact bridge firmware and your Matter platform. Native KNX functions, electrical ratings and Matter functions are separate specifications.

Function mapping is not a tested device–bridge pair or individual Matter certification for this KNX model. Protection functions and essential local automation should remain in the KNX installation.

Bridge options by function

These options match the product’s KNX functions to capabilities documented for a bridge. Open the bridge for its requirements and limitations.

1Home Voice & Visu

Function mapping, not a tested device–bridge pair

Temperature · Illuminance

Proposed from documented KNX and bridge function types. Verify the exact ETS application, required command/status objects, KNX Secure access and receiving-app support. This model–bridge pair has not been physically tested.

View mapping source ↗

1Home Server KNX Pro

Function mapping, not a tested device–bridge pair

Temperature · Illuminance

Proposed from documented KNX and bridge function types. Verify the exact ETS application, required command/status objects, KNX Secure access and receiving-app support. This model–bridge pair has not been physically tested.

View mapping source ↗

Atios KNX Bridge

Function mapping, not a tested device–bridge pair

Temperature · Illuminance

Proposed from documented KNX and bridge function types. Verify the exact ETS application, required command/status objects, KNX Secure access and receiving-app support. This model–bridge pair has not been physically tested.

View mapping source ↗

Technical specifications

Temperature · Illuminance

Manufacturer SKU variants
3096
Measurement range temperature
-30...+80 °C
Housing
plasticProduct-family specification; confirm the selected variant.
Protection class
IP44Product-family specification; confirm the selected variant.
Ambient temperature
-30...+50 °CProduct-family specification; confirm the selected variant.
Medium
TP1-256Product-family specification; confirm the selected variant.
Rated voltage
30V DC SELVProduct-family specification; confirm the selected variant.
Bus current consumption
≤ 10 mAProduct-family specification; confirm the selected variant.
Measurement range brightness
0 Lux … 150 000 LuxProduct-family specification; confirm the selected variant.
Specifications with sources (7)

Housing

plastic

View specification source ↗

published product family

Protection class

IP44

View specification source ↗

published product family

Ambient temperature

-30...+50 °C

View specification source ↗

published product family

Medium

TP1-256

View specification source ↗

published product family

Rated voltage

30V DC SELV

View specification source ↗

published product family

Bus current consumption

≤ 10 mA

View specification source ↗

published product family

Measurement range brightness

0 Lux … 150 000 Lux

View specification source ↗

published product family

Sources & limitations

Product research reviewed: Nov 5, 2026. This is separate from price, stock and installation-test dates.

Model, firmware & function limitations (3)
  • Only the listed temperature/humidity/illuminance values are Matter candidates. Wind, rain, GPS, air pressure and façade safety automation remain native KNX functions.
  • Requires an independently selected KNX-to-Matter bridge and ETS group-address mapping. Exact device/bridge pairing has not been physically tested.
  • Official manufacturer product page confirms the KNX product and the listed native functions. Matter export is a function-level integration candidate, not a manufacturer-tested exact pairing.
Manufacturer documentation & sources (1)
  • Elsner Elektronik — Suntracer KNX basic 20...30 V DC ↗Reviewed Nov 5, 2026
← Back to resultsOpen project shortlist

© 2026 BUILD10

HomeRecommended DevicesContactPrivacy Policy