Interra KNX Fan Coil Actuator (0/10V) | KNX via Matter | BUILD10
BUILD10
Local Service PartnersAI PartnersProduct
About UsContact
BUILD10
← KNX via Matter catalogProject shortlist (0)
Interra Interra KNX Fan Coil Actuator (0/10V) ITR507-4290

Interra

Interra KNX Fan Coil Actuator (0/10V)

KNX actuator for configured fan-coil fan-speed and valve outputs.

Product type
Climate
Model / SKU
ITR507-4290
KNX connection
KNX; consult the exact model documentation and ETS application

Connecting this device to Matter

This product uses KNX. A compatible bridge can expose selected functions to Matter through its IP connection. The KNX device itself does not become a Matter over Thread device.

Functions to map through a bridge

  • Fan control

Selected native KNX functions can be mapped using a suitable Matter bridge. Additional probes, contacts, couplers, controlled equipment or temperature controllers may be required as described below. Exact device–bridge combinations have not been tested.

Commission the KNX installation in ETS, then configure the bridge with the required group addresses, data types and status feedback. Check the exact bridge firmware and your Matter platform. Native KNX functions, electrical ratings and Matter functions are separate specifications.

Function mapping is not a tested device–bridge pair or individual Matter certification for this KNX model. Protection functions and essential local automation should remain in the KNX installation.

Bridge options by function

These options match the product’s KNX functions to capabilities documented for a bridge. Open the bridge for its requirements and limitations.

Atios KNX Bridge

Function mapping, not a tested device–bridge pair

Fan control

Proposed from documented KNX and bridge function types. Verify the exact ETS application, required command/status objects, KNX Secure access and receiving-app support. This model–bridge pair has not been physically tested.

View mapping source ↗

Technical specifications

Fan control

Registry model / order number
ITR507-4290

Sources & limitations

Product research reviewed: Nov 5, 2026. This is separate from price, stock and installation-test dates.

Model, firmware & function limitations (4)
  • A complete thermostat endpoint also requires a room controller, temperature measurement and compatible setpoint/status objects. Only fan control is proposed here.
  • Product identity and the native function are documented in the official KNX device registry. Matter applicability is an inference from the documented bridge function type, not an exact-SKU compatibility test. Verify the current manufacturer ETS application and required command/status objects before specification.
  • Current production status, availability and price have not been confirmed.
  • Official KNX registry model and function; proposed Matter mapping requires ETS object and bridge validation.
Manufacturer documentation & sources (2)
  • KNX Association — Interra KNX Fan Coil Actuator (0/10V) ↗Reviewed Nov 5, 2026
  • Interra ITR507-4290 technical documentation ↗Reviewed Nov 5, 2026
← Back to resultsOpen project shortlist

© 2026 BUILD10