JUNG KNX push-button interface, 8-gang | KNX via Matter | BUILD10
BUILD10
Local Service PartnersAI PartnersProduct
About UsContact
BUILD10
← KNX via Matter catalogProject shortlist (0)
JUNG KNX push-button interface, 8-gang 40008 1S E

JUNG

JUNG KNX push-button interface, 8-gang

KNX input interface for reporting the state of external switches, buttons or door/window contacts.

Product type
Sensors & inputs
Model / SKU
40008 1S E
KNX connection
TP wired bus

Connecting this device to Matter

This product uses KNX. A compatible bridge can expose selected functions to Matter through its IP connection. The KNX device itself does not become a Matter over Thread device.

Functions to map through a bridge

  • Contact state
  • Button events

Selected native KNX functions can be mapped using a suitable Matter bridge. Additional probes, contacts, couplers, controlled equipment or temperature controllers may be required as described below. Exact device–bridge combinations have not been tested.

Commission the KNX installation in ETS, then configure the bridge with the required group addresses, data types and status feedback. Check the exact bridge firmware and your Matter platform. Native KNX functions, electrical ratings and Matter functions are separate specifications.

Function mapping is not a tested device–bridge pair or individual Matter certification for this KNX model. Protection functions and essential local automation should remain in the KNX installation.

Bridge options by function

These options match the product’s KNX functions to capabilities documented for a bridge. Open the bridge for its requirements and limitations.

1Home Voice & Visu

Function mapping, not a tested device–bridge pair

Contact state · Button events

Proposed from documented KNX and bridge function types. Verify the exact ETS application, required command/status objects, KNX Secure access and receiving-app support. This model–bridge pair has not been physically tested.

View mapping source ↗

1Home Server KNX Pro

Function mapping, not a tested device–bridge pair

Contact state · Button events

Proposed from documented KNX and bridge function types. Verify the exact ETS application, required command/status objects, KNX Secure access and receiving-app support. This model–bridge pair has not been physically tested.

View mapping source ↗

Atios KNX Bridge

Function mapping, not a tested device–bridge pair

Contact state · Button events

Proposed from documented KNX and bridge function types. Verify the exact ETS application, required command/status objects, KNX Secure access and receiving-app support. This model–bridge pair has not been physically tested.

View mapping source ↗

Technical specifications

Door / window input · Buttons

KNX connection
TP wired bus
Inputs
8
Input signal
Potential-free contacts
Ambient temperature
−5 ... +45 °C
Storage/transport temperature
−25 ... +75 °C
Degree of protection
IP20
Protection class
III
Output voltage
DC 5 V SELV
Output current per channel
max. 3.2 mA
LED current (red LED with 1.7 V forward voltage)
2.2 mA per output
Length of cable set
25 cm, extendable to max. 30 m
Recommended cable
J-Y(St)Y 2 x 2 x 0.8 mm
Dimensions (W x H x D)
43.5 x 35.5 x 15.4 mm
KNX medium
TP 256
Commissioning mode
S-mode
Rated voltage KNX
DC 21 ... 32 V SELV
Current consumption KNX
5 ... 18 mA
Specifications with sources (14)

Ambient temperature

−5 ... +45 °C

View specification source ↗

Storage/transport temperature

−25 ... +75 °C

View specification source ↗

Degree of protection

IP20

View specification source ↗

Protection class

III

View specification source ↗

Output voltage

DC 5 V SELV

View specification source ↗

Output current per channel

max. 3.2 mA

View specification source ↗

LED current (red LED with 1.7 V forward voltage)

2.2 mA per output

View specification source ↗

Length of cable set

25 cm, extendable to max. 30 m

View specification source ↗

Recommended cable

J-Y(St)Y 2 x 2 x 0.8 mm

View specification source ↗

Dimensions (W x H x D)

43.5 x 35.5 x 15.4 mm

View specification source ↗

KNX medium

TP 256

View specification source ↗

Commissioning mode

S-mode

View specification source ↗

Rated voltage KNX

DC 21 ... 32 V SELV

View specification source ↗

Current consumption KNX

5 ... 18 mA

View specification source ↗

Sources & limitations

Product research reviewed: Nov 5, 2026. This is separate from price, stock and installation-test dates.

Model, firmware & function limitations (4)
  • Requires a commissioned KNX installation, mapped group addresses and a KNX-to-Matter bridge that supports the selected function. Exact device/bridge pair not physically tested.
  • This is an input interface, not a complete magnetic contact sensor. External contacts and correct input wiring are required.
  • Momentary button events are not equivalent to a persistent contact state; event export requires specific bridge support.
  • Exact model and KNX function identified in manufacturer documentation. Matter applicability is function-level and requires bridge configuration; not a tested pair.
Manufacturer documentation & sources (1)
  • JUNG — KNX push-button interface, 8-gang ↗Reviewed Nov 5, 2026
← Back to resultsOpen project shortlist

© 2026 BUILD10