ABB SA/S 4.16.6.2 Switch Actuator with Energy Functions SA/S 4.16.6.2

ABB

ABB SA/S 4.16.6.2 Switch Actuator with Energy Functions

Four switching channels with energy functions for monitoring and controlling electrical loads.

Product type
Lighting & switching
Model / SKU
SA/S 4.16.6.2
KNX connection
KNX TP

Connecting this device to Matter

This product uses KNX. A compatible bridge can expose selected functions to Matter through its IP connection. The KNX device itself does not become a Matter over Thread device.

Functions to map through a bridge

  • Lighting control
  • Switched load / outlet

Switch and status objects can be considered for compatible bridge functions. Energy measurements require explicit support in both the bridge and the receiving Matter platform and are not confirmed by this listing. No specific device–bridge pair has been tested.

Commission the KNX installation in ETS, then configure the bridge with the required group addresses, data types and status feedback. Check the exact bridge firmware and your Matter platform. Native KNX functions, electrical ratings and Matter functions are separate specifications.

Function mapping is not a tested device–bridge pair or individual Matter certification for this KNX model. Protection functions and essential local automation should remain in the KNX installation.

Bridge options by function

These options match the product’s KNX functions to capabilities documented for a bridge. Open the bridge for its requirements and limitations.

1Home Voice & Visu

Function mapping, not a tested device–bridge pair

Lighting control · Switched load / outlet

The bridge documents these function types. Commission the required KNX command and feedback objects in ETS, then map them in the bridge. Exact model pairing has not been tested; receiving-app support must also be checked.

View mapping source ↗

1Home Server KNX Pro

Function mapping, not a tested device–bridge pair

Lighting control · Switched load / outlet

The bridge documents these function types. Commission the required KNX command and feedback objects in ETS, then map them in the bridge. Exact model pairing has not been tested; receiving-app support must also be checked.

View mapping source ↗

Atios KNX Bridge

Function mapping, not a tested device–bridge pair

Lighting control · Switched load / outlet

The bridge documents these function types. Commission the required KNX command and feedback objects in ETS, then map them in the bridge. Exact model pairing has not been tested; receiving-app support must also be checked.

View mapping source ↗

xxter Pairot

Function mapping, not a tested device–bridge pair

Lighting control · Switched load / outlet

The bridge documents these function types. Commission the required KNX command and feedback objects in ETS, then map them in the bridge. Exact model pairing has not been tested; receiving-app support must also be checked.

View mapping source ↗

Technical specifications

Switching · Lighting · Energy monitoring

Order code
2CDG110270R0011
Outputs
4, potential-free
Contact rating
16 A, C-load
Load voltage
230 V AC
Controls
Manual output operation
Mounting
DIN rail
Commercial status
Stock, destination-specific delivery and current USD price have not been verified.
Output contacts
4 independent potential-free contacts
Native measurement
Independent load-current measurement per output; calculated power and energy for outputs or output groups
Local operation
Manual switching and output-state indication
Specifications with sources (3)

Output contacts

4 independent potential-free contacts

View specification source ↗

Native measurement

Independent load-current measurement per output; calculated power and energy for outputs or output groups

View specification source ↗

Local operation

Manual switching and output-state indication

View specification source ↗

Sources & limitations

Product research reviewed: Nov 4, 2026. This is separate from price, stock and installation-test dates.

Model, firmware & function limitations (1)
  • Switch and status objects can be considered for compatible bridge functions. Energy measurements require explicit support in both the bridge and the receiving Matter platform and are not confirmed by this listing. No specific device–bridge pair has been tested.
Manufacturer documentation & sources (3)
  • ABB SA/S4.16.6.2 product ↗Reviewed Nov 4, 2026
  • ABB SA/S x.16.6.2 software information ↗Reviewed Nov 4, 2026
  • Manufacturer technical product documentation ↗Reviewed Nov 5, 2026
← Back to resultsOpen project shortlist

© 2026 BUILD10

HomeRecommended DevicesContactPrivacy Policy