Theben FCA 1 KNX Fan-coil Actuator 4920200

Theben

Theben FCA 1 KNX Fan-coil Actuator

Fan-coil controller for two-pipe or four-pipe heating and cooling systems with up to three fan speeds.

Product type
Climate
Model / SKU
4920200
KNX connection
KNX TP

Connecting this device to Matter

This product uses KNX. A compatible bridge can expose selected functions to Matter through its IP connection. The KNX device itself does not become a Matter over Thread device.

Functions to map through a bridge

  • Thermostat control
  • Fan control

Expose temperature control only with complete room-controller objects. Separate fan control depends on the bridge’s supported speed/state mapping. Condensation and window interlocks remain in the KNX control system. No specific device–bridge pair has been tested.

Commission the KNX installation in ETS, then configure the bridge with the required group addresses, data types and status feedback. Check the exact bridge firmware and your Matter platform. Native KNX functions, electrical ratings and Matter functions are separate specifications.

Function mapping is not a tested device–bridge pair or individual Matter certification for this KNX model. Protection functions and essential local automation should remain in the KNX installation.

Bridge options by function

These options match the product’s KNX functions to capabilities documented for a bridge. Open the bridge for its requirements and limitations.

1Home Voice & Visu

Function mapping, not a tested device–bridge pair

Thermostat control

The bridge documents these function types. Commission the required KNX command and feedback objects in ETS, then map them in the bridge. Exact model pairing has not been tested; receiving-app support must also be checked.

View mapping source ↗

1Home Server KNX Pro

Function mapping, not a tested device–bridge pair

Thermostat control

The bridge documents these function types. Commission the required KNX command and feedback objects in ETS, then map them in the bridge. Exact model pairing has not been tested; receiving-app support must also be checked.

View mapping source ↗

Atios KNX Bridge

Function mapping, not a tested device–bridge pair

Thermostat control · Fan control

The bridge documents these function types. Commission the required KNX command and feedback objects in ETS, then map them in the bridge. Exact model pairing has not been tested; receiving-app support must also be checked.

View mapping source ↗

xxter Pairot

Function mapping, not a tested device–bridge pair

Thermostat control · Fan control

The bridge documents these function types. Commission the required KNX command and feedback objects in ETS, then map them in the bridge. Exact model pairing has not been tested; receiving-app support must also be checked.

View mapping source ↗

Technical specifications

Fan coil · Heating · Cooling · Fan control

Product designation
FCA 1 KNX
System
2-pipe or 4-pipe fan coil
Fan
Up to 3 stages
Valves
2-way or 3-way valves
Supply
220–230 V AC, 50/60 Hz
Inputs
Window/temperature and condensation monitoring
Mounting
DIN rail, 4 modules
Commercial status
Stock, destination-specific delivery and current USD price have not been verified.
KNX bus current
≤10 mA
Type of contact
Triac
Ambient temperature
-5°C ... 45°C
Type of protection
IP 20
Protection class
II according to EN 60 730-1
Specifications with sources (5)

KNX bus current

≤10 mA

View specification source ↗

Type of contact

Triac

View specification source ↗

Ambient temperature

-5°C ... 45°C

View specification source ↗

Type of protection

IP 20

View specification source ↗

Protection class

II according to EN 60 730-1

View specification source ↗

Sources & limitations

Product research reviewed: Nov 4, 2026. This is separate from price, stock and installation-test dates.

Model, firmware & function limitations (1)
  • Expose temperature control only with complete room-controller objects. Separate fan control depends on the bridge’s supported speed/state mapping. Condensation and window interlocks remain in the KNX control system. No specific device–bridge pair has been tested.
Manufacturer documentation & sources (1)
  • Theben FCA 1 KNX specifications ↗Reviewed Nov 4, 2026
← Back to resultsOpen project shortlist

© 2026 BUILD10

HomeRecommended DevicesContactPrivacy Policy
Theben FCA 1 KNX Fan-coil Actuator | KNX via Matter | BUILD10